Menu
Products
Archive
TTR310E and TTR330A

TTR310E and TTR330A

Three-phase transformer turns ratio test set
- DISCONTINUED

This product is now obsolete and has been replaced by the TTRU3

  • Stand-alone or remote-control operation
  • Accurately measures ratio, phase deviation and excitation current
  • Field upgradeable without compromise to calibration
  • Built-in capability for storing and downloading test results in an XML format, via RS-232, Ethernet or USB ports (depending on model)
  • Works in the presence of high interference/high voltage
  • Highest ratio measurement (45,000:1); highest accuracy (0.1%)
  • Displays % error vs. name plate with pass/fail limits

The TTR300 Series of three-phase transformer turns ratio test sets are designed to measure the turns ratio of power, instrument, and distribution transformers in a substation or manufacturing environment. A rugged and robust design makes these instruments well suited for use in a variety of harsh environments. Our leads are specially designed to provide the necessary flexibility needed in cold weather.

The TTR300 Series are ideal for use by power transformer manufacturers. Their unique testing procedures and storage capability allows an operator to set up and test difficult three-phase transformers (with multiple tap changers and bushing CTs) in a fraction of the time than it used to take with other TTRs. This test also includes a pass/fail limit of individual ratios.

Transformer Test Instrument Software Updates for TTR330A, MTO330A, MWA330A, DELTA4310A

The following components have been updated:

PowerDB ________________ V11.2.10 

MTOTestXP ______________ 2019.12.03.1

Delta Manual Control ______________ 2.0.9.51.0   

Instrument Config ______ 1.0.20023.1919

Splash Screen __________ 1.0.21075.830

Factory Config _________ 1.0.21122.850

Megger Update Manager __ 1.0.21165.1032

 

Recommendations

- Megger recommends that you return your instrument annually for calibration verification.
- Any instrument returned for re-calibration will be updated with the latest firmware and software versions.
- Certified Factory Calibration is valid for one year.

Attention

Incorrect installation of updates or incomplete updates may cause the equipment to become unusable.

If damage occurs from improper updates, the customer may be responsible for repair costs.

Software updates for TTR330A, MTO330A, MWA330A and DELTA4310A

Download this zip file, extract, and run the executable.

 

256bit Hash:
be0628b2014fffeca839036dae42c3d1a6c5c73d79a2e5f2fc6d0716667ef9d3

 

XfmrFamUpdater_10.005_fi3.zip

763 MB | 02/08/2022

XfmrFamUpdater_10-005_fi3.zip
745.9 MB | 09/08/22
Update Instructions

Please download and read these instructions before performing the update.

 

InstrumentUpdateInstructions_r10.pdf
623.9 KB | 09/08/22
TTR300

IMPORTANT NOTICE

Firmware version 6.5 is available via Megger’s repair department as part of a hardware update and will not appear on this website. Both Firmware versions 6.4 & 6.5 improve reliability, but 6.5 improves reliability drastically and completes tests in half the time.

The hardware update related to Firmware version 6.5 will be performed FREE OF CHARGE (this does not include cost of shipping to and from Megger factory or Megger Authorized Service Center [ASC]). Please note: Any required hardware repairs not related to Firmware version 6.5 will incur standard repair charges.
Please contact your nearest Megger sales representative for information on where to return your instrument for updates.

The Megger Valley Forge, USA factory and select Megger ASCs can perform updates. If you do not feel capable of performing updates properly, please contact your nearest Megger sales representative for information on where to return your instrument for updates.

Carefully read all instructions and backup your data before performing any updates.
Only update the firmware or software if you are experiencing difficulty with your instrument or if you have a specific need to do so.

!! WARNING !!

Incorrect installation of updates and incomplete updates may cause an error and make the equipment unusable.

If damage occurs from improper updates, customer is responsible for repair costs.

 

  •   Megger recommends that you return your Three-Phase TTR annually for calibration verification.
  •   Any instrument returned for re-calibration will be updated with the latest firmware version.
  •   Certified Factory Calibration is valid for one year.

 

1. PowerDB PC Upgrade [Optional]:

a. Download PowerDB 11 (You will be redirected to www.powerdb.com/download)

b. TTR PC Quick Manual


2. Install TTR 300 Firmware Upgrade:


a. TTR 300 Firmware Upgrade Instructions

b. Download TTR 300 Firmware Upgrade Installer - Firmware version 6.4

Download TTR 300 Firmware Upgrade Installer
TTR300_310_550503_FW_6-4.Zip
97.2 KB | 10/12/21
TTR 300 Firmware Upgrade Instructions
Upgrading-TTR-300-Firmware.pdf
268.0 KB | 10/12/21
TTR PC Quick Manual
TTR-PC-Quick-Manual.pdf
561.7 KB | 10/12/21
TTR310

IMPORTANT NOTICE

Firmware version 6.5 is available via Megger’s repair department as part of a hardware update and will not appear on this website. Both Firmware versions 6.4 & 6.5 improve reliability, but 6.5 improves reliability drastically and completes tests in half the time.

The hardware update related to Firmware version 6.5 will be performed FREE OF CHARGE (this does not include cost of shipping to and from Megger factory or Megger Authorized Service Center [ASC]). Please note: Any required hardware repairs not related to Firmware version 6.5 will incur standard repair charges.
Please contact your nearest Megger sales representative for information on where to return your instrument for updates.

The Megger Valley Forge, USA factory and select Megger ASCs can perform updates. If you do not feel capable of performing updates properly, please contact your nearest Megger sales representative for information on where to return your instrument for updates.

Carefully read all instructions and backup your data before performing any updates.
Only update the firmware or software if you are experiencing difficulty with your instrument or if you have a specific need to do so.

!! WARNING !!

Incorrect installation of updates and incomplete updates may cause an error and make the equipment unusable.

If damage occurs from improper updates, customer is responsible for repair costs.


- Megger recommends that you return your Three-Phase TTR annually for calibration verification.
- Any instrument returned for re-calibration will be updated with the latest firmware version.
- Certified Factory Calibration is valid for one year.

TTR310 color LCD

1. PowerDB PC Upgrade [Optional]:

a. Download PowerDB 11 (You will be redirected to www.powerdb.com/download)

b. TTR PC Quick Manual

2. Install TTR 310 Color LCD Firmware, Application, and Statup Upgrade:

Please refer to the version information on your TTR 310 Color LCD About/Update screen to determine if this update applies to you

a. TTR 310 Color LCD Firmware, Application, and Statup Upgrade Instructions

b. Download TTR 310 Color LCD Firmware, Application, and Startup Upgrade Installer

i.   Application Version:   1.0.0.84
ii.  Firmware Version:      6.4
iii. TX25Startup Version: 1.0.1.22

c. TTR 310 Quick Manual

 

TTR310 black and white LCD

1. PowerDB PC Upgrade [Optional]:

a. Download PowerDB 11 (You will be redirected to www.powerdb.com/download)

b. TTR PC Quick Manual

2. Install TTR 310 Black & White LCD Firmware Upgrade:

Please refer to the version on your TTR 310 Black & White LCD Self-Test screen during startup to determine if this update applies to you

a. TTR 310 Black & White LCD Firmware Upgrade Instructions

b. Download TTR 310 Black & White LCD Firmware Upgrade Installer - Firmware version 6.4

c. TTR 310 Quick Manual

3. TTR 310 Black & White LCD Fix [May not be necessary]:

If you experience issues with your screen after upgrading your TTR 310 to the latest firmware, use the Revert/Update functions of this program to fix the problem

a. Download TTR 310 Black & White LCD Fix

Download TTR 310 Black & White
TTR300_310_550503_FW_6-4_1.Zip
97.2 KB | 10/12/21
Download TTR 310 Black & White LCD Fix
TTRxDisplay.zip
395.8 KB | 10/12/21
Download TTR 310 Color LCD Firmware
TTR310C_06-19-2014.zip
300.9 KB | 10/12/21
TTR 310 Black & White LCD
Upgrading-TTR-310-Firmware.pdf
282.6 KB | 10/12/21
TTR 310 Color LCD Firmware
Upgrading-TTR-310C-Firmware-Application-Startup.pdf
473.3 KB | 10/12/21
TTR 310 Quick Manual
TTR-310-Quick-Manual.pdf
518.2 KB | 10/12/21
TTR PC Quick Manual
TTR-PC-Quick-Manual-(1).pdf
561.7 KB | 10/12/21
TTR320

TTR320 Combined Firmware and PowerDB Onboard Updates and Firmware only Updates In view of the complexity of these devices, it is essential to carefully read and fully understand all instructions before starting the update. A PC (personal Computer) to download with and a blank USB Thumb Drive is required. (A minimum size of 2GB with no files present is recommended.)

!! WARNING !!

Incorrect installation of updates and incomplete updates may cause a malfunction of the equipment and make it unusable. If this were to happen, the equipment should be returned to Megger or an authorized service center. Only update the firmware or software if you are experiencing difficulty with your instrument or if you have a specific need to do so. All stored readings should be saved to PowerDB or PowerDB Lite on a PC (personal computer) before updating the instrument. If you need assistance please submit a software support ticket here.

FYI (For your information)

  •   Megger recommends that you return your Three-Phase TTR every 3 years for calibration verification.
  •   Any instrument returned for re-calibration will be updated with the latest firmware version.
  •   Certified Factory Calibration is valid for one year.

PC Support Software To update or acquire PowerDB or PowerDB Lite Software, please follow this link: "PowerDB") PowerDB Lite is free software used to extract stored results from the instrument. PowerDB Package Version Information:

TTR Firmware: 5.4
PowerDB: 8.2.Onboard Dec. 18, 2009 17:03:22

Please download and read "TTR3xx Update Instructions 1.6" before beginning the actual update. Update Package Versions:

TTR Firmware: 5.12.0.0

Notes: MD5 validation files are now being made available for those that wish to verify that their download is still intact before unzipping and executing the software. To download the MD5 text files please right click and select save as, otherwise the text file will be displayed in a new tab or window. The same is true for any PDF files.

Instructions: Ethernet Interconnect
EthernetInterconnectInst.pdf
270.2 KB | 10/12/21
Instructions: Thumb Drive Update
ThumbUpdateInstructions_1-5.pdf
57.9 KB | 10/12/21
Instructions: TTR320 Update
TTR3xxUpdateInstructions.pdf
76.1 KB | 10/12/21
Update: Firmware only Update (TTR3x0_FW_5.12.0.0.zip)
TTR3x0_FW_5-12-0-0.zip
87.5 KB | 10/12/21
Update: Firmware Only Update MD5 Hash File {TTR3x0_FW_5.12.0.0_MD5.txt}
TTR3x0_FW_5-12-0-0_MD5.txt
181.0 bytes | 10/12/21
Update: TTR3xx Update Instructions 1.6 {TTR3xxUpdateInstructions_1.6.pdf}
TTR3xxUpdateInstructions_1-6.pdf
53.0 KB | 10/12/21
TTR330

IMPORTANT NOTICE

Firmware version 6.5 is available via Megger’s repair department as part of a hardware update and will not appear on this website. Both Firmware versions 6.4 & 6.5 improve reliability, but 6.5 improves reliability drastically and completes tests in half the time.

The hardware update related to Firmware version 6.5 will be performed FREE OF CHARGE (this does not include cost of shipping to and from Megger factory or Megger Authorized Service Center [ASC]). Please note: Any required hardware repairs not related to Firmware version 6.5 will incur standard repair charges.
Please contact your nearest Megger sales representative for information on where to return your instrument for updates.

The Megger Valley Forge, USA factory and select Megger ASCs can perform updates. If you do not feel capable of performing updates properly, please contact your nearest Megger sales representative for information on where to return your instrument for updates.

Carefully read all instructions and backup your data before performing any updates.
Only update the firmware or software if you are experiencing difficulty with your instrument or if you have a specific need to do so.

!! WARNING !!

Incorrect installation of updates and incomplete updates may cause an error and make the equipment unusable.

If damage occurs from improper updates, customer is responsible for repair costs.

- Megger recommends that you return your Three-Phase TTR annually for calibration verification.
- Any instrument returned for re-calibration will be updated with the latest firmware version.
- Certified Factory Calibration is valid for one year.

1. TTR 330 Quick Manual:

a. TTR 330 Quick Manual

 


2. Install TTR 330 Firmware Upgrade:

Please refer to the version of firmware on your TTR 330 to determine if this update applies to you. This can be accessed by going to Home -> Settings within PowerDB

a. TTR 330 Firmware Upgrade Instructions

b. Download TTR 330 Firmware Upgrade Installer - Firmware version 6.4


3. Download Brother PocketJet 6 Installer [Accessories]:

a. TTR 330 Brother PocketJet 6 Install Instructions

b. Download TTR 330 Brother PocketJet 6 Installer

Download TTR 330 Brother PocketJet 6 Installer
UD0001_PKG.zip
846.9 KB | 10/12/21
Download TTR 330 Firmware Upgrade Installer
TTR330_FW_Upgrade_6-4.Zip
755.7 KB | 10/12/21
TTR 330 Brother PocketJet 6 Install Instructions
BrotherPJ6_Installation.pdf
172.4 KB | 10/12/21
TTR 330 Firmware Upgrade Instructions
Upgrading-TTR-330-Firmware.pdf
369.7 KB | 10/12/21
TTR PC Quick Manual
TTR-PC-Quick-Manual.pdf
561.7 KB | 10/12/21
TTR330 Quick Manual
TTR-330-Quick-Manual.pdf
442.0 KB | 10/12/21